Journal of Magnetic Resonance Imaging · 1996 · 34 citations · 11 references
MedicineOncologyRadiologyDiagnostic ImagingDiagnostic RadiologySurgical OncologyCervical ImagingMagnetic Resonance ImagingPelvic ImagingPelvic TumorsTumor CharacterizationTumor DetectionBiopsy Of Recurrent TumorContrast-enhanced Pelvic ImagingDynamic ImagingImaging Of Tumor RecurrencePelvic OrgansPreoperative Tumor CharacterizationRecurrent Cervical CancerRecurrent Cervical Neoplasia
The value of dynamic-contrast enhanced MR imaging using FLASH technique was studied in 13 patients with postoperative recurrent cervical cancer verified histopathology and in 9 patients without recurrence. Dynamic FLASH imaging and conventional spin-echo T1- and T2-weighted sequences were compared in a prospective fashion with regard to accuracy of the diagnosis of recurrent tumor using biopsy results as the gold standard. The contrast between the recurrent tumor and the surrounding pelvic tissues was also analyzed. The accuracy of depicting recurrent tumor or dynamic images (82%) was superior to that of pre- and postcontrast T1-weighted images and T2-weighted images (64%, 68%, and 64%, respectively). The contrast between the recurrent tumor and pelvic fat was greater on precontrast T1-weighted and dynamic images than on T2-weighted and postcontrast T1-weighted images. The dynamic images clearly showed involvement of the surrounding pelvic organs, because enhancement was observed exclusively in the tumor in the early dynamic phase. Accuracy regarding involvement of the urinary bladder or rectal wall on pre- and postcontrast T1-weighted images and T2-weighted images was lower than that on the dynamic images. Dynamic MR imaging has potential for use in the detection and evaluation of the extent of recurrent postoperative cervical cancer.
11
Radiation fibrosis: differentiation from recurrent tumor by MR imaging.
H S Glazer, J K Lee, R G Levitt et al. · Radiology · 1985 · 265 citations
Carcinoma of the cervix: staging with MR imaging.
Kaori Togashi, K Nishimura, T Sagoh et al. · Radiology · 1989 · 207 citations
Tumor recurrence versus fibrosis in the female pelvis: differentiation with MR imaging at 1.5 T.
F. Ebner, H Y Kressel, Marshall C. Mintz et al. · Radiology · 1988 · 194 citations
Carcinoma of the cervix: dynamic MR imaging.
Yasuyuki Yamashita, Masaya Takahashi, Tsutomu Sawada et al. · Radiology · 1992 · 111 citations
Detection of hepatic metastases: analysis of pulse sequence performance in MR imaging.
David D. Stark, J Wittenberg, Robert R. Edelman et al. · Radiology · 1986 · 105 citations