IEEE Transactions on Instrumentation and Measurement · 1992 · 31 citations · 7 references
EngineeringElectrical EngineeringAnalog ElectronicsCircuit TheoryMicroelectronicsAnalog Integrated CircuitsAnalog IntegrationControl SystemsControl TheoryOperational AmplifiersSmall-signal AnalysisActive ControlAnalog Circuit DesignCapacitanceOperational Amplifier CircuitsOperational Amplifier DesignOperational Transconductance AmplifiersTime ConstantTransconductor Design
Three active integrator schemes with tunable time constants are presented. The second generation current conveyors (CCIIs) are used as active devices to achieve better frequency responses than that of operational amplifiers. The first scheme uses a capacitance multiplication technique for time constant control; the second uses an enhanced negative resistor to increase the time constant; and the last employs a modified loop technique to tune the time constant. All three schemes have been implemented in the laboratory using commercially available current conveyors (AD844s). The experimental results agree with theoretical prediction very well.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
7