2011 · 18 citations · 18 references
EngineeringBiomedical EngineeringAnalog ElectronicsBiomedical ImagingDigital ImagingAnalog Integrated CircuitsCmos Circuit DesignDigital Signal ProcessingImage ProcessingMixed-signal Integrated Circuit DesignAnalog-to-digital Converter DesignTime ConversionTime ResolutionTiming Resolution
This paper proposes a 128-channel column-parallel two-stage time-to-digital converter (TDC) utilizing a time difference amplifier (TDA) and shows measurement results with a 0.35um CMOS process. The 1st stage operates as a coarse TDC, the time residue which is not converted in the 1st stage is amplified by a TDA, then converted by the 2nd stage TDC. As the gain of the time difference amplifier can be adjusted from 8.6 to 21.6, the time resolution of the TDC can be tuned from 22.4ps to 8.9ps. The time resolution variation due to PVT effects is ±12% without compensation, however calibration can be used to compensate for this variation.
18