Anaesthesia · 1988 · 146 citations · 8 references
MedicineSurgeryDysphagiaLaryngologyPulmonologyAirway AssessmentAirway ObstructionEndotracheal IntubationBougie-assisted IntubationDifficult Airway Assessment
The reliability of two signs of tracheal placement of a gum elastic bougie was studied. These signs were clicks (produced as the tip of the bougie runs over the tracheal cartilages) and hold up of the bougie as it is advanced (when the tip reaches the small bronchi). Ninety-eight simulated and two genuine Grade 3 difficult intubations were attempted with the aid of a gum elastic bougie. Seventy-eight tracheal and 22 oesophageal placements of the bougie resulted. No clicks or hold up occurred with the bougie in the oesophagus. Clicks were recorded in 89.7% of tracheal placements of the bougie. Hold up at between 24-40 cm occurred in all tracheal placements. We conclude that these signs are reliable and that they should be taught as part of any difficult intubation drill in which the gum elastic bougie is used.
8
Difficult tracheal intubation in obstetrics
R. S. Cormack, J. R. Lehane · Anaesthesia · 1984 · 2.5K citations
Medicine, Anesthesiology, Obstetrics +10
Difficult tracheal intubation: a retrospective study
G. Samsoon, J. R. B. Young · Anaesthesia · 1987 · 1.6K citations · Full text
Medicine, Anesthesiology, Surgery +14
Mortality associated with anaesthesia
John Lunn, W. W. Mushin · Anaesthesia · 1982 · 327 citations · Full text
Difficulties in Tracheal Intubation
Ronald M. Meyer · JAMA · 1986 · 213 citations
Medicine, Anesthesiology, Anesthesia +12
G. Lyons · Anaesthesia · 1985 · 148 citations