Evaluation of a new chest tube removal protocol using digital air leak monitoring after lobectomy: a prospective randomised trial

156

Citations

17

References

2009

Year

Abstract

The application of a chest tube removal protocol using a digital drainage unit featuring a continuous recording of air leak was safe and cost effective. Although future studies are warranted to confirm these results in other settings, the use of this new protocol is now routinely applied in our practice.