IEEE Transactions on Instrumentation and Measurement · 2009 · 198 citations · 26 references
EngineeringComputer ScienceElectrical EngineeringAssistive TechnologyBiomedical Signal ProcessingHuman-computer InteractionBrain-computer InterfacesElectroencephalogram AnalysisElectroencephalogram Signal ProcessingElectroencephalographyElectrooculogram AnalysisHuman-machine InterfacesAssistive Communication SystemsBiopotential RecordingCommon-mode RejectionCommon-mode Rejection RatioElectroencephalogram ClassificationElectronic NoiseHuman-computer Interaction ApplicationsHuman-computer Interface Design
EOG-based systems provide a non‑speaking, non‑hand communication channel that is more efficient than EEG in some cases and can improve quality of life for the handicapped. This study aims to design and apply an efficient EOG‑based human‑computer interface that classifies horizontal and vertical eye‑movement signals to enable rapid, eye‑controlled communication. The system uses a microcontroller‑based virtual keyboard, a 176 Hz sampling rate, 88 dB CMRR, 0.6 µV noise, and a nearest‑neighbour classifier to translate eye‑movement signals into text. The classifier achieved 95 % accuracy, enabling users to communicate quickly and economically with their environment using only eye movements.
The aim of this paper is to present the design and application of an electrooculogram (EOG) based on an efficient human-computer interface (HCI). Establishing an alternative channel without speaking and hand movements is important in increasing the quality of life for the handicapped. EOG-based systems are more efficient than electroencephalogram (EEG)-based systems in some cases. By using a realized virtual keyboard, it is possible to notify in writing the needs of the patient in a relatively short time. Considering the biopotential measurement pitfalls, the novel EOG-based HCI system allows people to successfully communicate with their environment by using only eye movements. Classifying horizontal and vertical EOG channel signals in an efficient interface is realized in this study. The new system is microcontroller based, with a common-mode rejection ratio of 88 dB, an electronic noise of 0.6 μV (p-p), and a sampling rate of 176 Hz. The nearest neighborhood algorithm is used to classify the signals, and the classification performance is 95%. The novel EOG-based HCI system allows people to successfully and economically communicate with their environment by using only eye movements.
26
Pattern Recognition and Machine Learning
Journal of Electronic Imaging · 2007 · 22.1K citations
Pattern Recognition and Machine Learning
Kybernetes · 2007 · 8.4K citations
Medical Instrumentation-Application and Design
John G. Webster · Journal of Clinical Engineering · 1978 · 1.8K citations