2002 · 17 citations · 5 references
EngineeringElectrical EngineeringAutomationElectric MachinesPower ElectronicsDrive SystemsElectric DrivesElectric Motor DrivesElectric MotorsMotor Starting MethodsSynchronous MachinesElectric Drive UnitsElectric Machine DrivesElectrical Power SystemsMotor Drive Power ElectronicsMotor Drive SystemsSynchronous Machine ControlSynchronous Motor DrivesTerminal Voltage Control
This paper describes a sensorless synchronous machine drive to be used for starting an auxillary power unit (APU) on commercial transport airplanes. The proposed method utilizes the synchronous generator mounted on the APU, and presently only used as a source of electrical power, as a synchronous motor for starting the APU. The developed sensorless synchronous motor drive starting function involves measurement of machine terminal voltage and current, from which the desired current command is then calculated and implemented by the drive power converter. Power into the machine is determined by a power control loop, while the system voltage is limited to a desired value by a field weakening loop in the controller.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
5