Publication | Open Access
A Novel Birefrigent Photonic Crystal Fiber Surface Plasmon Resonance Biosensor
176
Citations
29
References
2014
Year
Photonic SensorEngineeringOptical TestingBiomedical EngineeringFiber OpticsBiosensing SystemsOptical PropertiesOptical SensorOptical SystemsBiosensor ConfigurationBiophysicsNanophotonicsPhotonicsCircular Air HolesPhotonic MaterialsFiber Optic SensingClassical OpticsBiophotonicsSurface Plasmon ResonancePhotonic DeviceOptical SensorsPlasmonicsBiomedical DiagnosticsOptical System Analysis
A numerical analysis of a novel birefringent photonic crystal fiber (PCF) biosensor constructed on the surface plasmon resonance (SPR) model is presented in this paper. This biosensor configuration utilizes circular air holes to introduce birefringence into the structure. This PCF biosensor model shows promise in the area of multiple detection using HE <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">x</sup> <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">11</sub> and HE <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">y</sup> <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">11</sub> modes to sense more than one analyte. A numerical study of the biosensor is performed in two interrogation modes: amplitude and wavelength. Sensor resolution values with spectral interrogation yielded 5 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-5</sup> RIU (refractive index units) for HE <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">x</sup> <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">11</sub> modes and 6 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-5</sup> RIU for HE <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">y</sup> <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">11</sub> modes, whereas 3 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-5</sup> RIU for HE <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">x</sup> <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">11</sub> modes and 4 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-5</sup> RIU for HE <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">y</sup> <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">11</sub> modes are demonstrated for the amplitude interrogation.
| Year | Citations | |
|---|---|---|
Page 1
Page 1