Rapid Communications in Mass Spectrometry · 2000 · 45 citations · 5 references
PharmacyBiochemistryPharmaceutical AnalysisAnalytical ChemistryChromatographic AnalysisMass Spectrometric AnalysisChromatographic SeparationChromatographyLiquid ChromatographyMass SpectrometryMetabolite IdentificationMetabolite QuantificationChromatographic Separation MechanismsHigh-resolution Mass AnalysisLiquid Chromatography-mass SpectrometryLiquid Chromatography-mass Spectrometry AnalysisLiquid Chromatography-mass Spectrometry Method DevelopmentMass Spectrometric QuantificationMetabolite Separation TechniquesSource Conversion
Because of the potential in-source conversion between a lactone and the corresponding hydroxy acid, it has been recognized that a liquid chromatography/tandem mass spectrometric (LC/MS/MS) method developed for quantitation of a lactone drug in the presence of its hydroxy acid metabolite (or vice versa) must incorporate chromatographic separation between the two compounds, unless in-source conversion between the two compounds has been eliminated by the appropriate selection of the LC/MS/MS parameters. We now report that chromatographic separation between a lactone and its hydroxy acid will be required under certain LC/MS/MS conditions used even in the absence of in-source conversion. This is due to the fact that the 18-mass-unit difference between a lactone and its hydroxy acid is, by coincidence, different by only one mass unit from the 17-mass-unit difference between the [M + H](+) and [M + NH(4)](+) ions of the lactone or the hydroxy acid. Thus, the [M + H](+) ion of a hydroxy acid is higher than the [M + NH(4)](+) ion of its lactone by only one mass unit. Therefore, in a method developed for quantitation of a hydroxy acid drug utilizing a selected-ion-monitoring (SRM) scheme that incorporates its [M + H](+) ion as the precursor ion, the quantitation would be inaccurate due to the interference by the contribution of the A + 1 isotope response from the [M + NH(4)](+) ion of the lactone metabolite present in the sample, unless there is a chromatographic separation between the two compounds. This is true even if Q1 is operated under a unit-mass resolution. The implication of this type of interference, arising from the presence of both the [M + H](+) and [M + NH(4)](+) ions of a drug and its metabolite, to the selection of LC and MS conditions (including mass resolution) will be discussed using the data obtained with a model lactone drug and its hydroxy acid metabolite.
5
Mohammed Jemal, Yuanqing Xia · Rapid Communications in Mass Spectrometry · 1999 · 127 citations
Naidong Weng, Jean W. Lee, Xiangyu Jiang et al. · Journal of Chromatography B Biomedical Sciences and Applications · 1999 · 104 citations
John Ayrton, R. A. Clare, Gordon J. Dear et al. · Rapid Communications in Mass Spectrometry · 1999 · 47 citations
Mohammed Jemal, Mike Huang, Yan Mao et al. · Rapid Communications in Mass Spectrometry · 2000 · 31 citations