IEEE Transactions on Energy Conversion · 2001 · 82 citations · 12 references
EngineeringElectrical EngineeringMotor ControlPower ElectronicsProcess ControlCurrent DriveDrive SystemsElectric DrivesElectric Motor DrivesPermanent Magnet MachinesSynchronous MachinesCurrent ControlInterior Permanent Magnet Synchronous MachinesMagnetic SaturationMagnetic Saturation EffectsMotor Drive ControlPermanent Magnet Synchronous Motor DrivesPermanent Magnet Synchronous MotorsTorque
The influence of magnetic saturation on maximum torque to current controlled interior permanent magnet synchronous motor drives is discussed in this paper. A maximum torque to current condition that takes into account magnetic saturation and determines the optimal d-axis current is derived. For the implementation of the proposed controller, an experimental procedure is used to adjust its parameters, therefore, the knowledge of the exact model is not required. Selected experimental results are presented to verify the theoretical considerations and to confirm the high performance of the suggested controller.
12
Motion control with permanent-magnet AC machines
Thomas M. Jahns · Proceedings of the IEEE · 1994 · 177 citations