IEEE Transactions on Power Electronics · 2013 · 480 citations · 39 references
EngineeringElectrical EngineeringPower ElectronicsRenewable Energy IntegrationRenewable Energy SystemsControl SystemsController TuningDc-ac InvertersMicrogridsPower Grid AnalysisPower System StabilityActive DampingActive Damping ControlCurrent Control Of Power ConvertersGrid-connected Converter ControlGrid-connected InvertersGrid-tied InvertersInverter Control StrategiesResonance
The injected grid current regulator and active damping of the LCL filter are essential to the control of LCL-type grid-connected inverters. Generally speaking, the current regulator guarantees the quality of the injected grid current, and the active damping suppresses the resonance peak caused by the LCL filter and makes it easier to stabilize the whole system. Based on the proportional-integral (PI) and proportional-resonant (PR) compensator together with capacitor-current-feedback active-damping which are widely used for their effectiveness and simple implementations, this paper proposes a simple step-by-step controller design method for the LCL-type grid-connected inverter. By carefully dealing with the interaction between the current regulator and active damping, the complete satisfactory regions of the controller parameters for meeting the system specifications are obtained, and from which the controller parameters can be easily picked out. Based on these satisfactory regions, it is more convenient and explicit to optimize the system performance. Besides, the insight of tuning the controller parameters from these satisfactory regions is also discussed. Simulation and experimental results verify the proposed step-by-step design method.
39