An EHD gas pump utilizing a ring/needle electrode

Jae-Duk Moon, Deok-Hyun Hwang, Sang-Taek Geum

IEEE Transactions on Dielectrics and Electrical Insulation · 2009 · 36 citations · 17 references

Concepts

Abstract

An electrohydrodynamic (EHD) gas pump, utilizing a ring/needle electrode, has been proposed and the effect of the ring electrode to the flow velocity and yield of flow generation of the EHD gas pump was investigated. The needle/ring is used as a corona discharge electrode and the mesh is used as the ion collecting electrode. It was observed that the proposed type of EHD gas pump can generate a higher flow velocity and yield of flow generation as compared with that from the same EHD gas pump without the ring electrode. As a result, a maximum flow velocity of V <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">W</sub> =4.54 m/s from the proposed EHD gas pump can be obtained at V=15.0 kV, which is 1.2 times higher than that of V <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">W</sub> =3.82 m/s of the same needle-to-mesh type EHD gas pump without the ring electrode. With the ring electrode, the yield of flow generation of Y <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">W</sub> =46.15 m/Ws can be obtained at V=11 kV, which is 2.5 times higher than that of the design without the ring electrode of Y <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">W</sub> =18.41 m/Ws. These enhancements, however, may be due to the effect of the ring electrode installed near the needle electrode.