Thermal performance of lightweight steel framed wall: The importance of flanking thermal losses

Paulo Santos, Cláudio Martins, Luís Simões da Silva, L. Bragança

Journal of Building Physics · 2013 · 43 citations · 8 references

DOIFull text

Open access

Concepts

Abstract

The thermal performance of a modular lightweight steel framed wall was measured and calculated with three-dimensional finite element method model. The focus of this article is on the effect of flanking thermal losses. The calculated heat flux values varied from −22% (external surface) to +50% (internal surface) when flanking loss was set to 0 as a reference case, thermal transmittance equal to 0.30 W/(m 2 ·K). Other critical parameters were the existence of fixing ‘L’-shaped steel elements and the perimeter thermal insulation (10 cm XPS).