Journal of Building Physics · 2013 · 43 citations · 8 references
EngineeringCivil EngineeringMechanical EngineeringFinite Element AnalysisHeat TransferThermal AnalysisHeat Transfer AnalysisHeat Transfer ModelingThermal DesignThermal InsulationThermal PerformanceThermal SimulationBuilding Thermal ResistanceCritical Heat FluxFinite Element Thermal ModelingFrame Thermal PerformanceHeat Flux MeasurementLightweight MaterialsThermal Insulation PerformanceThermal Properties Of Construction Materials
The thermal performance of a modular lightweight steel framed wall was measured and calculated with three-dimensional finite element method model. The focus of this article is on the effect of flanking thermal losses. The calculated heat flux values varied from −22% (external surface) to +50% (internal surface) when flanking loss was set to 0 as a reference case, thermal transmittance equal to 0.30 W/(m 2 ·K). Other critical parameters were the existence of fixing ‘L’-shaped steel elements and the perimeter thermal insulation (10 cm XPS).
8