Clinical Proteomics · 2015 · 30 citations · 21 references
Life SciencesMicrobiologyBacteriologyDiagnostic MicrobiologyMass Spectrometric AnalysisBacterial IdentificationMass SpectrometryMicrobial IdentificationMicrobial NomenclaturePathogen DetectionMaldi-tof Mass SpectrometryMass Spectrometry-based IdentificationMass Spectrometry-based Microbial IdentificationMatrix-assisted Laser Desorption Ionization Time-of-flight Mass SpectrometryMatrix-assisted Laser Desorption/ionizationMatrix-assisted Laser Desorption/ionization Time-of-flight Mass SpectrometryMicrobial Reference DatabasesMicrobiological Sample Processing
BACKGROUND: The MALDI (matrix-assisted laser desorption/ionization) Biotyper system for bacterial identification has already been utilized in clinical microbiology laboratories as a successful clinical application of protoemics. However, in cases of Nocardia, mass spectra suitable for MALDI Biotyper identification are often not obtained if such specimens are processed like general bacteria. This problem is related to the insufficiencies in bacterial spectrum databases that preclude accurate specimen identification. Here, we developed a bacterial processing method to improve mass spectra from specimens of the genus Nocardia. In addition, with the new processing method, we constructed a novel in-house bacterial database that combines a commercial database and mass spectra of Nocardia strains from the Department of Clinical Laboratory at Chiba University Hospital (DCLC) and the Medical Mycology Research Center at Chiba University (MMRC). RESULTS: The newly developed method (Nocardia Extraction Method at DCLC [NECLC]) based on ethanol-formic acid extraction (EFAE) improved mass spectra obtained from Nocardia specimens. The Nocardia in-house database at Chiba University Hospital (NDCUH) was then successfully validated. In brief, prior to introduction of the NECLC and NDCUH, 10 of 64 (15.6%) clinical isolates were identified at the species level and 16 isolates (25.0%) could only be identified at the genus level. In contrast, after the introduction, 58 isolates (90.6%) were identified at the species level and 6 isolates (9.4%) were identified at the genus level. CONCLUSIONS: The results of this study suggest that MALDI-TOF (time-of-flight) Biotyper system can identify Nocardia accurately in a short time in combination with a simple processing method and an in-house database.
21
Suzanne Q. van Veen, Eric C. J. Claas, Ed J. Kuijper · Journal of Clinical Microbiology · 2010 · 656 citations · Full text
Alain Bizzini, Christian Durussel, Jacques Billé et al. · Journal of Clinical Microbiology · 2010 · 600 citations · Full text
Kennard Tan, Brandon Ellis, Renee T. Lee et al. · Journal of Clinical Microbiology · 2012 · 320 citations · Full text
Adnan Alatoom, Scott A. Cunningham, Sherry M. Ihde et al. · Journal of Clinical Microbiology · 2011 · 258 citations · Full text