Fractal dimension and mechanical properties of human cortical bone

David Sánchez‐Molina, Juan Velázquez-Ameijide, Víctor Quintana, Carlos Arregui‐Dalmases, Jeff R. Crandall, Damien Subit, Jason Kerrigan

Medical Engineering & Physics · 2012 · 79 citations · 21 references

Concepts

Abstract

Fractal dimension (FD) can be used to characterize microstructure of porous media, particularly bone tissue. The porous microstructure of cortical bone is observable in micro-CT (μCT) images. Estimations of fractal dimensions of μCT images of coupons of human cortical bone are obtained. The same samples were tested on a tensile test machine and Young's modulus (YM) and Failure stress were obtained. When both types of measures were compared, a clear correlation was found (R=-81%, P<0.01). Young's modulus of each sample and the FD of its μCT images are correlated. From the assumption that cortical bone is approximately a fractal set, a non-linear constitutive relation involving FD is obtained for YM. Experimental results show good agreement with this constitutive relation. Additional parameters in the non-linear relation between YM and FD have been estimated from experimental results and related to physical parameters.

References

21