Journal of Structural Engineering · 2002 · 140 citations · 7 references
EngineeringCivil EngineeringEarthquake EngineeringSeismic DesignStructural EngineeringBending Of BeamsBuckling AnalysisBuckling Of ColumnsStress AnalysisStructural ConnectionsStructural DesignColumnsCyclic BehaviorCyclic Loading ResponseEarthquake ResponseMoment ConnectionsSteel Moment FramesTorsional BucklingWarping
Design engineers frequently use deep columns in steel special moment resisting frames to control drift. As the reduced beam section (RBS) moment connection is becoming popular after the 1994 Northridge, California earthquake, the SAC Joint Venture initiated a testing program to study the cyclic behavior of deep-column RBS moment connections. The test results showed that the deep column is prone to twisting. The twisting was caused by the eccentric beam flange force due to lateral-torsional buckling of the beam. In this paper, cycle tests results of three RBS moment connections with deep columns are presented. An analytical study showed that the warping stress is highly dependent on the h/tcf3 ratio of the column section. A design procedure is proposed that can be used to evaluate if column twisting is a concern. Additional bracing near the RBS region is recommended if the design procedure indicates high stresses.
7
Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings
Ronald O. Hamburger, John Hooper, Thomas A. Sabol et al. · 2000 · 779 citations
The Dogbone: Back to the Future
André Plumier · Engineering Journal · 1997 · 74 citations · Full text