Circulation · 1999 · 28 citations · 15 references
MedicineCardiologySurgeryCardiothoracic SurgeryClinical CardiologyPulmonologyAortic SurgeryCardiac Valve SurgeryEchocardiographic Hemodynamic AssessmentHeart TransplantationThoracic SurgeryEchocardiographic HemodynamicsEchocardiographic QuantificationPostoperative Right Ventricular FunctionRight Ventricular EchocardiographyRight Ventricular Function MonitoringRight Ventricular HemodynamicsRight Ventricular Systolic Function
BACKGROUND: The pulmonary autograft operation (the Ross procedure) involves excision of a portion of the right ventricular (RV) outflow tract, prolonged cross-clamp times, and insertion of a pulmonary homograft. There is concern about the effect of such operations on right ventricular function. METHODS AND RESULTS: Twenty-five patients undergoing either pulmonary autograft or homograft replacement of the aortic valve as part of a prospective randomized trial had echocardiographic RV long-axis measurements performed before surgery and 6 months (range 3 to 12 months) after surgery. In all patients, systolic excursion (SE) and both shortening and lengthening rates (SR and LR, respectively) were reduced postoperatively (P<0.05) (homografts: SE 1.5+/-0.4 versus 2.3+/-0.6 cm, SR 6.8+/-2.1 versus 9. 6+/-3.1 cm/s, LR 6.0+/-1.8 versus 8.9+/-3.0 cm/s; autografts: SE 1. 4+/-0.4 versus 2.2+/-0.4 cm, SR 5.8+/-3.0 versus 8.2+/-3.0 cm/s, LR 5.7+/-1.9 versus 8.5+/-3.7 cm/s). There were no differences between the 2 groups. Eighteen patients who had undergone either aortic homograft or pulmonary autograft surgery were studied between 6 and 35 months after surgery. RV volumes were assessed with the use of MRI in addition to echocardiographic RV long-axis measurements. Global volumes were increased to a similar amount in both groups (homografts: end-diastolic volume 145+/-34 mL, end-systolic volume 78+/-23 mL; autografts: end-diastolic volume 157+/-33 mL, end-systolic volume 89+/-25 mL; P=NS), whereas stroke volumes were maintained in both groups (homografts 67+/-15 mL, autografts 67+/-16 mL; P=NS). RV SE was depressed in both groups to a similar degree to that seen with the previous group (homografts 1.5+/-0.3 cm, autografts 1.4+/-0.2 cm). CONCLUSIONS: Aortic valve replacement with either a pulmonary autograft or an aortic homograft leads to a degree of persistent RV longitudinal dysfunction that is not more pronounced in those undergoing the Ross procedure. The mechanisms and long-term effects of these changes must be further studied.
15
Assessment of right ventricular function using two-dimensional echocardiography
Sanjiv Kaul, Chuwa Tei, James M. Hopkins et al. · American Heart Journal · 1984 · 1K citations
Medicine, Cardiology, Physiology +13
REPLACEMENT OF AORTIC AND MITRAL VALVES WITH A PULMONARY AUTOGRAFT
D. N. Ross · The Lancet · 1967 · 962 citations
Medicine, Cardiology, Surgery +10
Measurement of right and left ventricular volumes in healthy individuals with cine MR imaging.
Udo Sechtem, P W Pflugfelder, Robert G. Gould et al. · Radiology · 1987 · 409 citations
Medicine, Cardiology, Radiology +17
Pulmonary Autograft Procedure for Aortic Valve Disease
John C. Chambers, Jane Somerville, Susan Stone et al. · Circulation · 1997 · 264 citations
Medicine, Cardiology, Surgery +10