IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · 2005 · 12 citations · 13 references
EngineeringMechanical EngineeringInstrumentationSensorsVibrationGas SensorsMechanical SensorsPiezoelectric CeramicsPiezoelectric MaterialsTaguchi MethodsVibration MeasurementFinite Element Dynamic AnalysisMeasurement System DesignPiezoelectric SensingPiezoelectric SensorsSignal-to-noise RatioSignal-to-noise Ratio AnalysisSignal-to-noise Ratio OptimizationTaguchi Designs
It is important that measurement systems provide an accurate and robust performance over a wide range of input conditions. Under these conditions, the measurement system is said to have a robust design with dynamic characteristics. This paper adopts Taguchi's signal-to-noise ratio analysis to optimize the dynamic characteristics of a piezoelectric gas sensor system whose output response is linearly related to the input signal. The goal of the present dynamic characteristics study is to increase the sensitivity of the measurement system while simultaneously reducing its variability. This study focuses upon the conventional quartz crystal nanobalance (QCN) gas sensor. A time- and cost-efficient finite element analysis method is utilized to investigate the effects of the deposited mass upon the resonant frequency output of the QCN biosensor.
13
Quality Engineering Using Robust Design
Tom Menten, M. S. Phadke · Technometrics · 1991 · 3.5K citations
Quality Engineering Using Robust Design
Kailash C. Kapur · Journal of Quality Technology · 1990 · 2.1K citations
Taguchi Techniques for Quality Engineering
James Simpson · Journal of Quality Technology · 1996 · 597 citations