IEEE Transactions on Electromagnetic Compatibility · 2009 · 51 citations · 9 references
EngineeringElectrical EngineeringFacilities PlanningMicrowave EngineeringZoningElectromagnetic CompatibilityFacilities ProtectionFacility DesignFacility ZoningElectromagnetic Boundary ConditionsElectromagnetic InterferenceElectromagnetic Interference ControlElectromagnetic Interference MitigationElectromagnetic Interference ReductionElectromagnetic Interference SuppressionPhysical Access ControlsRadiated Susceptibility Analysis
It is argued that it is the intent behind the electromagnetic interference in intentional electromagnetic interference (IEMI) that causes problems to large distributed systems and facilities even if they are designed by traditional zoning concept rules. Hardening such facilities against IEMI requires a correspondence between the electromagnetic zone boundary and the physical access control boundary. The three characteristics of a facility, the <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">accessibility</i> , <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">susceptibility</i> , and <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">consequence</i> , are discussed in the context of vulnerability to IEMI. A methodology for classification of facilities with respect to IEMI is presented.
9