IEEE Transactions on Medical Imaging · 1999 · 708 citations · 27 references
MedicineBioengineeringBiomedical EngineeringBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBrain ImagingMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMedical Image AnalysisMedical ImagingThree-dimensional Reconstruction3D Magnetic Resonance ImagingAlgorithm Performance EvaluationBloch Equation SimulationBloch EquationsComputational PhantomsDiagnostic Algorithm EvaluationIn Vivo StudiesThree-dimensional Medical Imaging
With the increased interest in computer-aided image analysis methods, there is a greater need for objective methods of algorithm evaluation. Validation of in vivo MRI studies is complicated by a lack of reference data and the difficulty of constructing anatomically realistic physical phantoms. We present here an extensible MRI simulator that efficiently generates realistic three-dimensional (3-D) brain images using a hybrid Bloch equation and tissue template simulation that accounts for image contrast, partial volume, and noise. This allows image analysis methods to be evaluated with controlled degradations of image data.
27
E. L. Hahn · Physical Review · 1950 · 4.9K citations
Fundamentals of digital image processing
Computer Vision Graphics and Image Processing · 1989 · 4.7K citations
Design and construction of a realistic digital brain phantom
D. Louis Collins, Alex Zijdenbos, Vasken Kollokian et al. · IEEE Transactions on Medical Imaging · 1998 · 1.8K citations