IEEE Transactions on Power Electronics · 2010 · 77 citations · 26 references
EngineeringElectrical EngineeringElectric MachinesPower ElectronicsPowertrain EngineeringElectric DrivesElectric Motor Drive SystemsElectric Motor DrivesElectric MotorsInduction MachinesMachine WindingsInduction Motor DrivesMotor AsymmetryMotor Drive InvertersMotor WindingsRotating Electric MachinesStator WindingsThree-phase WindingsVoltage Source Inverters
This paper addresses shaft end-to-end and shaft-to-frame voltages that appear in the 400-V 15-kW induction motor driven by a voltage-source pulsewidth modulation inverter. It has been known that an inverter-fed common-mode voltage causes both shaft voltages. Extensive experiments are performed with an ungrounded motor subjected to a differential-mode voltage. Experimental results show that the differential-mode voltage applied across three-phase, two-phase, or single-phase stator windings also causes a shaft end-to-end voltage. It is concluded that the combination of a steep change in differential-mode voltage and high-frequency motor asymmetry causes a shaft end-to-end voltage. A motor model is presented to explain the generation of shaft end-to-end voltage.
26
Bearing currents and their relationship to PWM drives
D. Busse, J. Erdman, R.J. Kerkman et al. · IEEE Transactions on Power Electronics · 1997 · 328 citations
Engineering, Electrical Engineering, Mechanical Engineering +17
Reduction of common mode currents in PWM inverter motor drives
Mario Cacciato, A. Consoli, G. Scarcella et al. · 2002 · 206 citations