Hydrogen production and COD elimination rate in a continuous microbial electrolysis cell: The influence of hydraulic retention time and applied voltage

Adrián Escapa, Ana Katerine de Carvalho Lima Lobato, D.M. García, Antonio Morán

Environmental Progress & Sustainable Energy · 2012 · 51 citations · 28 references

Concepts

Abstract

The influence of the applied voltage ( V app ) and the hydraulic retention time (HRT) on hydrogen and methane production and the removal rate for chemical oxygen demand (COD) was studied in a membrane‐less microbial electrolysis cell with a Ni‐based cathode. When a synthetic effluent from a dark‐fermentation process was fed continuously into the anodic chamber, an increase in both the V app (from 0.6 to 1.0 V) and HRT (from 8 to 12 h) increased the hydrogen production rate from 0.18 to 1.42 L L A −1 d −1 (liters per liter of anode per day) and the COD elimination rate from 46 to 94%. The influences of V app and HRT on hydrogen production and the COD removal rate were found to be interdependent. Whereas acetic and butyric acids were easily degraded, propionic acid exhibited pseudo‐recalcitrant behavior. © 2012 American Institute of Chemical Engineers Environ Prog, 32: 263‐268, 2013

References

28