Mean Topography of Normal corneas*

Barry A. J. Clark

Clinical and Experimental Optometry · 1974 · 38 citations · 5 references

Concepts

Abstract

A survey was made of corneal topography in ‘normal’ eyes, i.e. eyes meeting certain requirements such as near‐emmetropia, absence of disease and Injury, and no prolonged wear of contact lenses. Previous investigations Indicated that there was no need to monitor the fixation angle and accommodative state of subjects. No artificial method of widening the palpebral aperture was used. The results are presented as asphericities measured from the sphere that best fits the optic‐cap region of each individual cornea. Asymmetry of asphericities about the ophthalmometric axis in any meridian is usually the case in individual corneas and is also present in the pooled results. In particular, the nasal semi‐meridian in eyes of both males and females has greater positive asphericity than the temporal semimerldian. The results are expected to be of use for investigations of the fit of contact lenses and for studies of the dioptric image formed by the cornea.

References

5