IEEE Power Engineering Review · 2002 · 41 citations · 8 references
EngineeringElectrical EngineeringElectric MachinesMachine DesignPower ElectronicsDrive SystemsElectric DrivesElectric Motor Drive SystemsElectric Motor DrivesInduction MachinesSynchronous MachinesDrive System ModelingDynamic Model IdentificationInduction Motor DrivesInduction Motor TheoryInduction MotorsMotor Parameter EstimationSynchronous Machine ModelingTime-varying Parameters
This paper presents a method to determine the continuous-time parameters of induction machines that are necessary to implement the field-oriented control strategy. This method does not require the use of any mechanical devices or speed measurement sensor and it is conceived to be used during the autocommissioning of the drive system. The estimation of the stator resistance is based on the dynamic model of the machine considering that the variables are dc quantities. The estimation of the stator transient inductance, the stator inductance, and the rotor time constant are based on the dynamic model of the machine. The experimental results that are presented demonstrate the feasibility of the proposed method.
8