Computed TomographyEngineeringCt Scans3D ModelingComputer-aided DesignBiomedical EngineeringDigital FabricationDicom FilesVascular SurgeryCt ScanVascular ImagingIndustrial TechniqueTreatment StrategiesRadiologyCardiovascular ImagingGeometric ModelingVascular ImageMedical ImagingStereolithography MachineDesign3D PrintingIndustrial DesignBiomedical ImagingMedicineStereolithographic Vascular Replicas3D Imaging
Our goal was to develop a system that would allow us to recreate live patient arterial pathology by using an industrial technique known as stereolithography (or rapid prototyping). In industry, drawings rendered into dicom files can be exported to a computer programmed to drive various industrial tools. Those tools then make a 3D structure shown by the original drawings. We manipulated CT scan dicom files to drive a stereolithography machine and were able to make replicas of the vascular diseases of three patients.
18
Saccular aneurysm formation in curved and bifurcating arteries.
George N. Foutrakis, Howard Yonas, Robert J. Sclabassi · PubMed · 1999 · 199 citations · Full text
George A. Brown, Keikhosrow Firoozbakhsh, Thomas A. DeCoster et al. · Journal of Bone and Joint Surgery · 2003 · 138 citations
Preclinical Therapeutics, Translational Medicine, Medicine +8