Comparison of AC Losses of HTS Pancake Winding With Single Tape and Multi-Stacked Tape

S. Lee, HJ Lee, Gichun Cha, Ji-Kwang Lee

IEEE Transactions on Applied Superconductivity · 2005 · 19 citations · 8 references

Concepts

Abstract

AC losses generated in the HTS winding differ from that of the short sample because each turn of winding is magnetically affected by adjacent turns. In this paper, we calculated the AC loss of HTS pancake windings. Numerical calculation was carried out to figure out the magnetic field in the windings. During the AC loss calculation of both windings, AC losses were obtained by using the short sample AC losses data. According to the results of calculation, loss calculation by using the short sample data of multi-stacked tape was more approached to winding loss than that by using the single tape data. To prove the effectiveness of the calculations, AC losses of windings was measured and compared. Finally the single phase HTS transformer with multi-stacked tape was constructed and tested.

References

8