2004 · 10 citations · 0 references
EngineeringElectrical EngineeringInstrumentationMetrologyNuclear InstrumentationAccelerator PhysicsCalibrationElectrical MeasurementEquipment CalibrationImpedance MeasurementInput ImpedanceTransmission Line AnalysisTransmission Line Theory
For frequencies below 10 MHz the classical two wire transmission line method is subject to difficulties in sensitivity and measurement uncertainties. Thus for evaluation of the low frequency transverse impedance properties of the LHC dump kicker a modified version of the two wire transmission line has been used. It consists, in the present case, of a 10 turn loop of approximately 1 meter length and 2 cm width. The change of input impedance of the loop is measured as a function of the surroundings and by using a proper reference (metallic beam pipe) these changes are converted into a meaningful transverse beam coupling impedance. Measurements of several calibration objects have shown close agreement with theoretical results.