Ultrasonic investigation of the nonlinearity of fused silica for different hydroxyl-ion contents and homogeneities between 300 and 3°K

John H. Cantrell, M. A. Breazeale

Physical review. B, Condensed matter · 1978 · 47 citations · 25 references

Concepts

Abstract

The harmonic-generation technique was used to measure the third-order elastic constants ${C}_{111}$ of four types of fused silica. The samples differed in amount of OH content and directional homogeneity. The results indicate that a relatively large OH content in fused silica may give rise to a relatively greater value of ${C}_{111}$ and that ${C}_{111}$ is a weak function of temperature regardless of OH content. The relationship between the experimentally defined ultrasonic nonlinearity parameter $\ensuremath{\beta}=\ensuremath{-}\frac{(3{C}_{11}+{C}_{111})}{3{C}_{11}}$ and the Gr\"uneisen parameter $\ensuremath{\gamma}$ also has been determined. The measured temperature dependence of $\ensuremath{\beta}$ indicates that in the Debye model elastic constants other than ${C}_{11}$ and ${C}_{111}$ must dominate the strong temperature dependence of the Gr\"uneisen parameter for fused silica at low temperatures.

References

25