Classical and Quantum Gravity · 2003 · 160 citations · 12 references
Natural SciencesMaterials EngineeringMaterials ScienceMechanical Behavior Of MaterialsSurface ScienceThin FilmsCoatingsInterferometrySurface CoatingsThin Film Mechanical PropertiesDetector Material EffectsDetectorsMechanical LossesMechanical Property LossMulti-layer CoatingsSensitivitySilica-based MaterialsSubstrate-coating Interactions
Current interferometric gravitational wave detectors use test masses with mirror coatings formed from multiple layers of dielectric materials, most commonly alternating layers Of SiO2 (silica) and Ta2O5 (tantala). However, mechanical loss in the Ta2O5/SiO2 coatings may limit the design sensitivity for advanced detectors. We have investigated sources of mechanical loss in the Ta2O5/SiO2 coatings, including loss associated with the coating-substrate interface, with the coating-layer interfaces and with the coating materials. Our results indicate that the loss is associated with the coating materials and that the loss of Ta2O5 is substantially larger than that Of SiO2.
12
Theory of Elasticity (3rd ed.)
S. Timoshenko, J. N. Goodier, H. N. Abramson · Journal of Applied Mechanics · 1970 · 4K citations
<i>Systems with Small Dissipation</i>
V. B. Braginsky, V. P. Mitrofanov, V. I. Panov et al. · American Journal of Physics · 1987 · 246 citations