Electroanalysis · 2007 · 27 citations · 29 references
EngineeringChemical EngineeringMaterials ScienceBiosensorsElectroanalytical MethodsSensorsElectrochemical BiosensorsElectrochemical SensorsElectrode KineticsElectrode MaterialsEnzyme CatalysisNanomaterial-based BiosensorsDehydrogenase-based BiosensorsGlassy Carbon ElectrodesMethod Detection LimitNadh MeasurementNadh OxidationNadh QuantificationNanomaterial-modified Electrodes
Abstract Titanium‐containing MCM‐41 (Ti‐MCM‐41) modified glassy carbon electrode (GCE) can exhibit an excellent electrocatalytic activity towards the oxidation of β‐Nicotinamide adenine dinucleotide (NADH). A dramatic decrease in the over‐voltage of NADH oxidation reaction is observed at 0.28 V (vs. SCE). The modified electrode is found to be stable and reproducible. The electrode shows a linear response for a wide range of 10–1200 μM NADH and the detection limit is 8.0 μM. Ti‐MCM‐41 mesoporous molecular sieves provide an efficient matrix for development of NADH biosensors and the prepared electrode not only can be used to detect the concentration of NADH in biochemical reaction, but also as the potential matrix of the construction of dehydrogenases biosensor.
29
Zeolite chemistry and catalysis
Applied Catalysis · 1991 · 1.6K citations
"Plugging into Enzymes": Nanowiring of Redox Enzymes by a Gold Nanoparticle
Yi Xiao, Fernando Patolsky, Eugenii Katz et al. · Science · 2003 · 1.3K citations