Neurology · 2005 · 73 citations · 7 references
MedicinePhysical MedicineElectrodiagnostic MedicinePhysical ExaminationRheumatologyElectrical MeasurementIdiopathic Inflammatory MyopathiesMuscle Strength TestingMusculoskeletal AssessmentMyopathy EvaluationAutoimmune MyositisBedside Clinical AssessmentBedside Neuromuscular AssessmentBioelectrical Impedance MonitoringElectrical ImpedanceElectromyographyInflammatory Myopathy EvaluationSkeletal Myopathy
Electrical impedance myography (EIM) is a new technique with potential for the noninvasive bedside assessment of myopathy. EIM was performed on the quadriceps of 10 patients with inflammatory myopathy and 10 normal subjects. The major EIM parameter, the spatially averaged phase, was 35% lower in the myositis patients and correlated with whole-body (r = 0.765, p = 0.01) and quadriceps (r = 0.673, p = 0.03) strength.
7
Defining Clinical Improvement in Adult and Juvenile Myositis.
Lisa G. Rider, Edward H. Giannini, Michael O. Harris‐Love et al. · PubMed · 2003 · 183 citations
Medicine, Neurology, Pediatrics +13
Resistivity and phase in localized BIA
C. A. Shiffman, R. Aaron, V Amoss et al. · Physics in Medicine and Biology · 1999 · 64 citations