Electroanalysis · 2013 · 12 citations · 37 references
PharmacyPharmaceutical AnalysisAnalytical ChemistryElectroanalytical MethodsElectrochemistryChemical SensorsElectrochemical DetectionElectrochemical SensorsNanoparticle DesignNanosensorsChemical IdentityDetectionDifferential Pulse VoltammetryElectrochemical CharacterizationNanomaterial-modified ElectrodesVoltammetric DetectionVoltammetric SensingVoltammetry
Abstract Detection of the genotoxic impurity hydrazine (HZ) in the presence of active pharmaceutical ingredients (APIs) represents a significant challenge to the pharmaceutical industry. Here we show how the use of electrochemical strategies in conjunction with metal nanoparticle (NP) functionalised polycrystalline boron‐doped diamond (BDD) electrodes enables detection of HZ in the presence of two different electrochemically active APIs. By simply changing the chemical identity of the metal NP, which shifts the detection potential for HZ, it is possible to selectively screen out the API signature from the HZ current – voltage response. HZ detection limits of 11.1 µM (Au NP BDD) and 3.3 µM (Pt NP BDD) in the presence of excess acetaminophen and promazine respectively, were determined using differential pulse voltammetry in quiescent solution.
37
Statistics and Chemometrics for Analytical Chemistry
Eric R. Ziegel · Technometrics · 2004 · 4.4K citations
Why gold is the noblest of all the metals
Bjørk Hammer · Nature · 1995 · 3.8K citations
Jean Sanabria‐Chinchilla, Koichiro Asazawa, T. Sakamoto et al. · Journal of the American Chemical Society · 2011 · 317 citations
Christopher Batchelor‐McAuley, Craig E. Banks, Andrew O. Simm et al. · The Analyst · 2005 · 249 citations