Cancer Epidemiology Biomarkers & Prevention · 2011 · 98 citations · 16 references
MedicineImmunologyOncologyCancer ImmunologyInflammationMolecular DiagnosticsBiomarker ValidationCancer BiomarkersCytokine BiologyImmuno-oncology BiomarkersInflammatory BiomarkersMultiplexed BiosensingImmune MarkersInflammatory Biomarker DetectionInflammatory Marker DetectionIntraclass CorrelationLower Limit Of QuantificationLower Limit Of QuantitationMultiplex Biomarker AssaysMultiplexed Assays
BACKGROUND: Chronic inflammation is etiologically related to several cancers. We evaluated the performance [ability to detect concentrations above the assay's lower limit of detection, coefficients of variation (CV), and intraclass correlation coefficients (ICC)] of 116 inflammation, immune, and metabolic markers across two Luminex bead-based commercial kits and three specimen types. METHODS: From 100 cancer-free participants in the Prostate, Lung, Colorectal, and Ovarian Cancer Trial, serum, heparin plasma, and EDTA plasma samples were utilized. We measured levels of 67 and 97 markers using Bio-Rad and Millipore kits, respectively. Reproducibility was assessed using 40 blinded duplicates (20 within-batches and 20 across-batches) for each specimen type. RESULTS: A majority of markers were detectable in more than 25% of individuals on all specimen types/kits. Of the 67 Bio-Rad markers, 51, 52, and 47 markers in serum, heparin plasma, and EDTA plasma, respectively, had across-batch CVs of less than 20%. Likewise, of 97 Millipore markers, 75, 69, and 78 markers in serum, heparin plasma, and EDTA plasma, respectively, had across-batch CVs of less than 20%. When results were combined across specimen types, 45 Bio-Rad and 71 Millipore markers had acceptable performance (>25% detectability on all three specimen types and across-batch CVs <20% on at least two of three specimen types). Median concentrations and ICCs differed to a small extent across specimen types and to a large extent between Bio-Rad and Millipore. CONCLUSIONS: Inflammation and immune markers can be measured reliably in serum and plasma samples using multiplexed Luminex-based methods. IMPACT: Multiplexed assays can be utilized for epidemiologic investigations into the role of inflammation in cancer etiology.
16
Sameena S. Khan, Meghan S. Smith, Debra Reda et al. · Cytometry Part B Clinical Cytometry · 2004 · 354 citations · Full text
Nefertiti C. duPont, Kehui Wang, Pathik D. Wadhwa et al. · Journal of Reproductive Immunology · 2005 · 316 citations · Full text
Comparison of Multiplex Immunoassay Platforms
Qin Fu, Jie Zhu, Jennifer E. Van Eyk · Clinical Chemistry · 2009 · 211 citations · Full text