Archives of Disease in Childhood Fetal & Neonatal · 2012 · 77 citations · 21 references
MedicineChild HealthPediatricsBiosensorsInfant HealthNeonatologyBlood Glucose MonitoringContinuous Glucose MonitoringDiabetes MellitusGlycemic ControlGlycemic MonitoringMetabolic MonitoringBlood Glucose RegulationGlucose ConcentrationGlucose MonitoringGlucose Monitoring DevicesGlucose Monitoring In NewbornsIntrapartum Glucose MonitoringPediatric Glucose MonitoringPoint-of-care Glucose Measurement
OBJECTIVE: Recent studies have highlighted the need for improved methods of monitoring glucose control in intensive care to reduce hyperglycaemia, without increasing the risk of hypoglycaemia. Continuous glucose monitoring is increasingly used in children with diabetes, but there are little data regarding its use in the preterm infant, particularly at extremes of glucose levels and over prolonged periods. This study aimed to assess the accuracy of the continuous glucose monitoring sensor (CGMS) across the glucose profile, and to determine whether there was any deterioration over a 7 day period. DESIGN: Prospectively collected CGMS data from the NIRTURE Trial was compared with the data obtained simultaneously using point of care glucose monitors. SETTING: An international multicentre randomised controlled trial. PATIENTS: One hundred and eighty-eight very low birth weight control infants. OUTCOME MEASURES: Optimal accuracy, performance goals (American Diabetes Association consensus), Bland Altman, Error Grid analyses and accuracy. RESULTS: The mean (SD) duration of CGMS recordings was 156.18 (29) h (6.5 days), with a total of 5207 paired glucose levels. CGMS data correlated well with point of care devices (r=0.94), with minimal bias. It met the Clarke Error Grid and Consensus Grid criteria for clinical significance. Accuracy of single readings to detect set thresholds of hypoglycaemia, or hyperglycaemia was poor. There was no deterioration over time from insertion. CONCLUSIONS: CGMS can provide information on trends in glucose control, and guidance on the need for blood glucose assessment. This highlights the potential use of CGMS in optimising glucose control in preterm infants.
21
Intensive Insulin Therapy in Critically Ill Patients
Greet Van den Berghe, Pieter Wouters, Frank Weekers et al. · New England Journal of Medicine · 2001 · 10K citations · Full text
Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood Glucose
William L. Clarke, Daniel J. Cox, Linda Gonder‐Frederick et al. · Diabetes Care · 1987 · 1.4K citations
Medicine, Endocrinology, Biosensors +16