PubMed · 1993 · 29 citations · 8 references
MedicineCardiologyNuclear MedicineCardiac Nuclear MedicineClinical CardiologyNuclear CardiologyCardiac Nuclear ImagingCardiovascular ImagingCoronary Artery ImagingMyocardial Blood Flow QuantificationMyocardial Perfusion ImagingTissue Perfusion AssessmentCardiac Myocardial Perfusion ImagingCoronary Flow Reserve AssessmentMyocardial Flow ReserveMyocardial Perfusion ReserveOxygen-15 Water QuantificationQuantitative Myocardial Perfusion ImagingResting Myocardial Perfusion
We have previously shown that myocardial perfusion can be quantified by positron emission tomography (PET) with 15O-labeled water (H2(15)O), as experimentally validated with radiolabeled microspheres in animal hearts. The purpose of our study was to determine whether myocardial nutritive perfusion reserve assessed with PET in human subjects was parallel to flow velocity reserve assessed in conductance vessels measured with intracoronary Doppler probes. We studied nine patients with chest pain and angiographically normal coronary arteries with intracoronary Doppler flow velocity assessments before and after administration of 16 micrograms of intracoronary adenosine. We also assessed myocardial nutritive perfusion with PET and H2(15)O before and after intravenous administration of dipyridamole (0.56 mg/kg). Perfusion reserve (the ratio of absolute values of myocardial perfusion after dipyridamole administration to perfusion at rest) estimated with PET (3.5 +/- 0.9 s.d.) correlated closely with flow velocity reserve (the ratio of hyperemic intracoronary flow velocity to flow velocity at rest) (3.5 +/- 1.2, r = 0.80, p < 0.01). Absolute values of perfusion assessed tomographically averaged 1.22 +/- 0.19 ml/g/min in patients at rest and 4.16 +/- 0.93 after dipyridamole administration. Our data indicate that noninvasive assessment of myocardial perfusion with PET provides results that parallel intracoronary Doppler flow velocity measurements. Because PET delineates nutritive perfusion throughout the heart in absolute terms, its use may facilitate detection of impaired coronary arterial function and enhance delineation of the efficacy of potentially therapeutic interventions in patients with chest pain and angiographically normal coronary arteries.
8
Effects of adenosine on human coronary arterial circulation.
R F Wilson, Karen Fraser Wyche, Betsy V. Christensen et al. · Circulation · 1990 · 907 citations
Medicine, Cardiology, Pharmacology +11
Quantification of regional myocardial blood flow in vivo with H215O.
Steven R. Bergmann, Keith A.A. Fox, Alice L. Rand et al. · Circulation · 1984 · 368 citations