The FASEB Journal · 1989 · 57 citations · 17 references
Life SciencesBiochemistryNeuroscienceBioenergeticsMetabolismNeurophysiologyBrain Energy MetabolismBrain ImagingCerebral PhysiologyEnergy MetabolismEnzyme ImagingMagnetic Resonance SpectroscopyCreatine Phosphate ResynthesisEnzyme ActivityEnzyme Imaging QuantificationEnzyme Kinetics ImagingGray Matter AnatomyMagnetization Transfer ImagingMetabolic Brain ImagingRegional Brain Metabolism
Creatine kinase activity and high-energy phosphate concentration have been investigated using localized 31P spectroscopy in the human brain in vivo. The phase-modulated rotating frame imaging technique, incorporating magnetization transfer and inversion recovery, has been used to produce a 1-dimensional rate profile map of steady-state enzyme activity. Large differences in the flux from phosphocreatine (PCr) to ATP have been discovered between volumes of human brain consisting of predominantly gray (2.0 cm) and white (4.5 cm) matter. The concentration of PCr changes slightly (2.0 cm = 5.20 +/- 0.45 mmol.l-1, 4.5 cm = 4.63 +/- 0.31 mmol.l-1), while the ATP concentration remains within limits (3.30 +/- 0.4 mmol.l-1). No change in pHi was detected between the two regions in normal volunteers (n = 6). The forward rate constant of the PCr----ATP reaction in regions of predominantly gray matter (0.30 +/- 0.04 s-1) was twice that of white matter (0.16 +/- 0.02 s-1) in vivo.
17
FREEZE‐BLOWING: A NEW TECHNIQUE FOR THE STUDY OF BRAIN <i>IN VIVO</i>
Richard L. Veech, R. L. Harris, Dulce Veloso et al. · Journal of Neurochemistry · 1973 · 360 citations
The Use of NMR Spectroscopy for the Understanding of Disease
George K. Radda · Science · 1986 · 251 citations