IEEE Transactions on Power Electronics · 2010 · 31 citations · 33 references
EngineeringElectrical EngineeringCircuit TheoryEnergy SystemsPower ElectronicsAc-dc ConversionAc-dc ConvertersConverter TopologiesDc-dc ConversionDc-dc ConvertersPower Factor CorrectionBuck ConvertersCapacitorsPrototype EvaluationSteady-state OperationSteady-state Operation DesignThree-phase Converters
This paper proposes a three-phase, reduced-switch, buck-type converter that can operate with input-power-factor correction. The key feature of the proposed converter is that a switch in the converter has a lower peak voltage stress than a switch in a conventional three-phase, single-switch buck converter. The voltage stress in the proposed converter is limited to the peak value of the phase voltage of the input capacitors rather than the peak value of the line-to-line voltage, as is the case in the conventional converter. The reduction in the voltage stresses is therefore almost half as compared to that of conventional converter. This allows lower rated, standard devices to be used in the converters and reduces switching losses. In this paper, the steady-state operation of the converter is presented and general properties and design considerations are discussed. The feasibility of the proposed converter is confirmed with results obtained from an experimental prototype.
33
VSI-PWM rectifier/inverter system with a reduced switch count
Gi-Taek Kim, T.Α. Lipo · 2002 · 220 citations
Johann W. Kolar, H. Ertl, Franz Zach · 2002 · 170 citations