Journal of Bone and Joint Surgery - British Volume · 2002 · 84 citations · 6 references
Skeletal TraumaHip ArthroplastyBiomechanicsSurgical StabilizationBlood LossSurgeryIntertrochanteric FracturesPccp GroupJoint ReplacementProspective TrialMedicineOsteoporosisOrthopaedic SurgeryAnesthesiologySpinal Fracture
We performed a randomised, prospective trial in 111 patients with intertrochanteric fractures of the hip comparing the use of the Gotfried percutaneous compression plate (PCCP) with that of the classic hip screw (CHS). Blood loss and transfusion requirement were less in the PCCP group but the operating time was significantly longer. The complication rate after operation was similar in both groups, and at a minimum follow-up of six months there was no difference in the rates of fracture healing or implant failure. The PCCP gives results which are similar to those obtained with a conventional device. Its suggested advantages seem to be theoretical rather than practical and, being a fixed-angle implant, it is not universally applicable.
6
[Treatment of trochanteric fractures of the femur].
I T Knysh, I V Shumada · PubMed · 1967 · 377 citations
Skeletal Trauma, Surgical Stabilization, Operative Treatment +5
Classification of Trochanteric Fractures
Jørgen Steen Jensen · Acta Orthopaedica Scandinavica · 1980 · 320 citations
Visual evoked responses in ethambutol induced optic neuritis.
Srivastava Ak, Goel Uc, S Bajaj et al. · PubMed · 1997 · 25 citations
Visual evoked responses in tuberculous children on ethambutol therapy.
V. Seth, P. K. Khosla, O. P. Semwal et al. · PubMed · 1991 · 23 citations