NMR in Biomedicine · 2000 · 61 citations · 9 references
MedicineNuclear MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyPulmonologyMagnetic Resonance ImagingMedical ImagingPulmonary ImagingPulmonary Nuclear ImagingPulmonary Parenchymal ImagingDynamic Planar ImagingEcho Planar ImagingLung Ventilation ImagingPulmonary Ventilation ImagingPulse SequencesRapid Magnetic Resonance ImagingRegional Lung VentilationRespiratory Disease Imaging
We applied the rapid imaging capability of echo planar MR pulse sequences and hyperpolarized (3)He ventilation imaging to observe the dynamic distribution of gas in the lungs during breathing. Findings in five normal volunteers (age 19-53 years) and four patients with severe smoking-related emphysema (age 56-71 years) were compared. All studies were performed on a 1.5 T whole body scanner using a 30 cm Helmholtz surface coil and 0.5 l of 20-40% polarized (3)He mixed with 1-2 l nitrogen. Our echo planar imaging pulse sequence allowed acquisition of each image in 0.04 s, with a pixel size of 7 mm(2) (TR = 40.5 ms, TE = 12.1 ms, flip angle = 22 degrees, echo train length = 32, matrix = 32 x 64, field of view = 225 x 450 mm, slice thickness = 10 mm). Imaging was performed in the transaxial plane repeatedly at 3, 10 or 20 evenly spaced levels, immediately before and during breathing of the gas mixture. In normal subjects during the first breath, (3)He appeared throughout each slice first in the mid lungs, then in the lower lungs, then in the upper lungs, with slightly greater signal in the dependent posterior regions. In patients with emphysema, sequential filling of different lung regions was seen during the first breath, with delayed filling of other regions observed during rebreathing and room air washout. We conclude that subsecond dynamic (3)He MR ventilation imaging can reveal normal and abnormal ventilation phenomena not seen with conventional scintigraphic methods, and offers another approach to the study of ventilation physiology and pathophysiology.
9
Spin-exchange optical pumping of noble-gas nuclei
Thad Walker, W. Happer · Reviews of Modern Physics · 1997 · 1.4K citations
Human lung air spaces: potential for MR imaging with hyperpolarized He-3.
James R. MacFall, H. Cecil Charles, Robert D. Black et al. · Radiology · 1996 · 295 citations
Normal and abnormal pulmonary ventilation: visualization at hyperpolarized He-3 MR imaging.
H.‐U. Kauczor, D. Hofmann, K.‐F. Kreitner et al. · Radiology · 1996 · 273 citations
Lung Air Spaces: MR Imaging Evaluation with Hyperpolarized<sup>3</sup>He Gas
Eduard E. de Lange, John P. Mugler, James R. Brookeman et al. · Radiology · 1999 · 249 citations
Nuclear magnetic resonance imaging with hyperpolarised helium-3
M. Ebert, W. Heil, Ernst W. Otten et al. · The Lancet · 1996 · 186 citations