PET/CT Pattern Analysis for Surgical Staple Line Recurrence in Patients With Colorectal Cancer

29

Citations

15

References

2010

Year

Abstract

FDG PET/CT pattern analysis enables accurate assessment for staple line recurrence in patients with previous resection of colorectal cancer. The most reliable PET/CT pattern predicting staple line recurrence is an eccentric or perianastomotic mass on CT with corresponding eccentric or perianastomotic FDG uptake on PET. Background, diffuse (on one or both sides of the staple line), curvilinear, and focal patterns of FDG uptake do not correlate with recurrence in the absence of a mass on CT.