Journal of Biomedical Optics · 2004 · 83 citations · 33 references
MedicineOral PathologyPathologyBiomedical ImagingBiomedical OpticsDiagnostic ImagingCancer DetectionCancer DiagnosisFluorescence SpectroscopyMedical ImagingOral Disease DiagnosticsTumor ClassificationArea Under The Receiver Operating Characteristic CurveAutofluorescenceAutofluorescence ImagingLesion ClassificationMalignant Oral LesionsNormalizationPrincipal ComponentsTissue Autofluorescence
Autofluorescence spectroscopy shows promising results for detection and staging of oral (pre-)malignancies. To improve staging reliability, we develop and compare algorithms for lesion classification. Furthermore, we examine the potential for detecting invisible tissue alterations. Autofluorescence spectra are recorded at six excitation wavelengths from 172 benign, dysplastic, and cancerous lesions and from 97 healthy volunteers. We apply principal components analysis (PCA), artificial neural networks, and red/green intensity ratio's to separate benign from (pre-)malignant lesions, using four normalization techniques. To assess the potential for detecting invisible tissue alterations, we compare PC scores of healthy mucosa and surroundings/contralateral positions of lesions. The spectra show large variations in shape and intensity within each lesion group. Intensities and PC score distributions demonstrate large overlap between benign and (pre-)malignant lesions. The receiver-operator characteristic areas under the curve (ROC-AUCs) for distinguishing cancerous from healthy tissue are excellent (0.90 to 0.97). However, the ROC-AUCs are too low for classification of benign versus (pre-)malignant mucosa for all methods (0.50 to 0.70). Some statistically significant differences between surrounding/contralateral tissues of benign and healthy tissue and of (pre-)malignant lesions are observed. We can successfully separate healthy mucosa from cancers (ROC-AUC>0.9). However, autofluorescence spectroscopy is not able to distinguish benign from visible (pre-)malignant lesions using our methods (ROC-AUC<0.65). The observed significant differences between healthy tissue and surroundings/contralateral positions of lesions might be useful for invisible tissue alteration detection.
33
Basic principles of ROC analysis
Charles E. Metz · Seminars in Nuclear Medicine · 1978 · 6.1K citations
Rebekah A. Drezek, Konstantin Sokolov, Urs Utzinger et al. · Journal of Biomedical Optics · 2001 · 286 citations · Full text
Endoscopic fluorescence detection of high-grade dysplasia in Barrett's esophagus
Masoud Panjehpour, B. F. Overholt, Tuan Vo‐Dinh et al. · Gastroenterology · 1996 · 247 citations · Full text