Publication | Open Access
Comparison of chamfer and deep chamfer preparation designs on the fracture resistance of zirconia core restorations
18
Citations
15
References
2011
Year
The results indicated a relationship between the marginal design of zirconia cores and their fracture re-sistance. A deep chamfer margin improved the biomechanical performance of posterior single zirconia crown restorations, which might be attributed to greater thickness and rounded internal angles in deep chamfer margins.