Concepedia

Publication | Open Access

Comparison of chamfer and deep chamfer preparation designs on the fracture resistance of zirconia core restorations

18

Citations

15

References

2011

Year

Abstract

The results indicated a relationship between the marginal design of zirconia cores and their fracture re-sistance. A deep chamfer margin improved the biomechanical performance of posterior single zirconia crown restorations, which might be attributed to greater thickness and rounded internal angles in deep chamfer margins.

References

YearCitations