Magnetic Resonance in Medicine · 1999 · 288 citations · 35 references
MedicineBioengineeringNeuroscienceBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBrain ImagingCerebral Blood FlowFunctional NeuroimagingMagnetic Resonance Contrast MechanismsMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsBlood Oxygenation Level-dependent ContrastBlood Oxygenation Level-dependent ImagingDiffusion-weighted ContrastEcho Time DependenceEcho Time OptimizationFunctional Magnetic Resonance ImagingFunctional MriSpin Echo Imaging
The nature of vascular contribution to blood oxygenation level dependent (BOLD) contrast used in functional MRI (fMRI) is poorly understood. To investigate vascular contributions at an ultrahigh magnetic field of 9.4 T, diffusion-weighted fMRI techniques were used in a rat forepaw stimulation model. Tissue and blood T(2) values were measured to optimize the echo time for fMRI. The T(2) of arterial blood was 40.8 +/- 3.4 msec (mean +/- SD; n = 5), similar to the tissue T(2) of 38.6 +/- 2.1 msec (n = 16). In comparison, the T(2) of venous blood at an oxygenation level of 79.6 +/- 6.1% was 9. 2 +/- 2.3 msec (n = 11). The optimal spin-echo time of 40 msec was confirmed from echo-time dependency fMRI studies. The intravascular contribution was examined using a graded diffusion-weighted spin-echo echo-planar imaging technique with diffusion weighting factor (b) values of up to 1200 sec/mm(2). Relative BOLD signal changes induced by forepaw stimulation showed no dependence on the strength or direction of the diffusion-sensitizing gradients, suggesting that the large vessel contribution to the BOLD signal is negligible at 9.4 T. However, gradient-echo fMRI performed with bipolar diffusion sensitizing gradients, which suppress intravascular components from large vessels, showed higher percent signal changes in the surface of the brain. This effect was attributed to the extravascular contribution from large vessels. These findings demonstrate that caution should be exercised when interpreting that higher percent changes obtained with gradient-echo BOLD fMRI are related to stronger neural activation. Magn Reson Med 42:919-928, 1999.
35
The rat brain in stereotaxic coordinates
Miklós Palkovits · Neuropeptides · 1983 · 29K citations
Medicine, Neurobiology, Neuroscience +12
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Satoshi Ogawa, T M Lee, A R Kay et al. · Proceedings of the National Academy of Sciences · 1990 · 6.5K citations · Full text
Medicine, Neuroscience, Radiology +17
Denis Le Bihan, D Lallemand, P. Grenier et al. · Radiology · 1986 · 3.9K citations