Circulation Research · 1992 · 93 citations · 25 references
MedicineCardiologyNuclear MedicineBiomedical ImagingCardiac Nuclear MedicineCompartmental ModelingCardiac ImagingCardiovascular ImagingMyocardial Blood Flow QuantificationMyocardial Perfusion ImagingPerfusion ImagingPositron Emission TomographyBlood FlowMyocardial Perfusion TracersPet KineticsPositron Emission Tomography Myocardial ImagingPositron Emission Tomography Tracer KineticsQuantitative Myocardial Perfusion ImagingRubidium-82 Perfusion ImagingRubidium-82 Quantification
Positron emission tomography offers the ability to noninvasively assess regional myocardial perfusion in absolute terms (i.e., milliliters per gram per minute). Accurate estimates have been difficult to achieve with generator-produced 82Rb because of the complex behavior of this tracer in the myocardium. The aim of the present study was to determine whether regional myocardial blood flow could be assessed quantitatively with 82Rb and positron emission tomography by using a two-compartment kinetic model. Regional perfusion in milliliters per gram per minute was estimated from dynamic tomographic scans after intravenous administration of 82Rb in 18 studies in 13 intact dogs studied without intervention, after 2 and 24 hours of induced ischemia, during reperfusion after transient occlusion, or at rest and after pharmacological hyperemia after induced coronary artery stenosis. Regional flow was estimated along with the forward and backward rates of transport (k1 and k2 [minutes-1]) after the relative volume of distribution of the first compartment was fixed to 0.53 ml/ml and the tomographic parameters, the recovery and spillover fractions, were fixed to averaged values obtained in previous studies. In 36 comparisons, estimates of regional flow with 82Rb correlated well with flow measured with concomitantly administered radiolabeled microspheres (r = 0.91, p less than 0.05) over the flow range from 0.14 to 4.25 ml/g/min. A putative index of viability, k2, increased significantly in regions with severe ischemia. The results suggest that quantification of regional myocardial perfusion is possible in centers using 82Rb for estimates of myocardial perfusion when a physiologically appropriate, two-compartment model is used.
25
Blood flow measurements with radionuclide-labeled particles
Michaël Heymann, B. Payne, Julien I.E. Hoffman et al. · Progress in Cardiovascular Diseases · 1977 · 2.1K citations
Gary D. Hutchins, Markus Schwaiger, Karen C. Rosenspire et al. · Journal of the American College of Cardiology · 1990 · 554 citations
Medicine, Cardiology, Radiology +17
Regression analysis by example
Giovanni C. Porzio · Journal of Applied Statistics · 2013 · 448 citations