IEEE Transactions on Medical Imaging · 1997 · 14 citations · 17 references
EngineeringBiomedical EngineeringRadiologyBiomedical ImagingDiagnostic ImagingDigital ImagingChest RadiographyDiagnostic Imaging SystemsImage QualityImagingMedical ImagingRadiographic ImagingDigital Chest RadiographyDigitizationDynamic RangeFilm-based RadiographyImage DisplayLuminanceLuminance ContrastX-ray Imaging Systems
Simple chest X rays on film are the most common type of image in medical diagnosis. However, amongst the various types of medical X-ray images, they require the highest level of display quality due to the fact that the body structures they capture on film have varying degrees of permeability to X rays. Conventional high-definition digital display technology has not always been able to match the quality of such film images. This has been a major impediment against progress toward the complete digitization of simple chest X rays. The intent of this paper is to examine that, when applied to medical diagnosis of chest X rays, super-high-definition (SHD) images (digital images with resolution exceeding that of HDTV) are capable of producing a level of quality of diagnostic accuracy on a par with conventional film images. We will start out by seeking out the overall transmission characteristics of a system that uses digital radiography and a film digitizer to digitize images. We will then derive gray-scale transform characteristics based on the luminance linear method for approximating, as closely as possible on a CRT, film images on a light box that have wide dynamic range and high luminance. Finally, we will present the results of image evaluation experiments using high-definition CRT monitors. These results indicate that conventional film images and those on super-high-definition CRT monitors have nearly the same quality. They will also show that the contrast mapping selected by radiologists and theoretical luminance linear characteristics were almost the same except in low-luminance regions. We will also discuss radiologists' comments on CRT monitors after they participated in the evaluation experiment.
17
The Essential Physics of Medical Imaging
Jerrold T. Bushberg, J. Anthony Seibert, Edwin M. Leidholdt et al. · Medical Physics · 2003 · 2K citations · Full text
Natural Sciences, Physics, Radiology +14
Computed radiography utilizing scanning laser stimulated luminescence.
Mitumasa Sonoda, Masao Takano, Junji Miyahara et al. · Radiology · 1983 · 865 citations
The Essential Physics of Medical Imaging
William R. Hendee · Radiology · 1994 · 172 citations
Natural Sciences, Physics, Radiology +14
Physical model for the contrast sensitivity of the human eye
Peter G. J. Barten · Proc. SPIE · 1992 · 147 citations