Journal of Cardiovascular Electrophysiology · 2007 · 132 citations · 19 references
MedicineCardiologyRadiologyDiagnostic ImagingDiagnostic RadiologyInterventional CardiologyAblation TherapyCardiac ImagingCardiovascular ImagingFluoroscopic ImagingFluoroscopy-guided ProceduresAtrial Flutter AblationFluoroscopic Image InterpretationFluoroscopy-guided AblationFluoroscopy-guided Catheter PlacementPercutaneous AblationPulmonary Vein Imaging
INTRODUCTION: This study examines the feasibility of atrial fibrillation (AF) ablation using registered three-dimensional computed tomography (CT) images of the left atrium with fluoroscopy. METHODS AND RESULTS: A total of 50 consecutive patients with symptomatic AF refractory to medical therapy (32 paroxysmal, 18 persistent, age 55 +/- 10 years) were randomized to undergo a catheter-based AF ablation procedure with or without the CT-fluoroscopy guidance system. All patients underwent preprocedural contrast-enhanced CT imaging and segmentation of the left atrium. For the CT-fluoroscopy group, circumferential lesions encompassing the pulmonary vein (PV) antrum and linear lesions along the roof of the left atrium between the superior PVs and the mitral isthmus were created on the CT image, which was registered with real-time fluoroscopy. The registered images were then used to navigate the ablation catheters to the sites of planned ablation. After the ablation sites were completed, any remaining PV potentials were isolated with electrophysiological guidance. In the control patients, the same technique was performed without using the CT-fluoro guidance system. CT scans were accurately registered to fluoroscopic images with minimal manual correction. Operators could navigate catheters on the registered images to preplanned, extraostial sites for ablation. CT-fluoroscopy guidance decreased procedure duration and fluoro times (P < 0.05). At a mean follow-up of 9 +/- 2 months, 21 patients (84%) in the CT-fluoro guidance group and 16 patients (64%) in the control group have had no recurrence of AF. CONCLUSION: CT-fluoroscopic-guided left atrial ablation is feasible and allows appropriate catheter manipulation in the left atrium.
19
Initiation of Atrial Fibrillation by Ectopic Beats Originating From the Pulmonary Veins
Shih‐Ann Chen, Ming-Hsiung Hsieh, CHING‐TAI TAI et al. · Circulation · 1999 · 1.5K citations
Medicine, Cardiology, Pharmacology +16
Circumferential Radiofrequency Ablation of Pulmonary Vein Ostia
Carlo Pappone, Salvatore Rosanio, Giuseppe Oreto et al. · Circulation · 2000 · 1.4K citations · Full text
Medicine, Cardiology, Surgery +16