43rd AIAA/ASME/ASCE/AHS/ASC Structures, Structural Dynamics, and Materials Conference · 2002 · 32 citations · 2 references
EngineeringAerospace EngineeringAerospace StructuresStructural AnalysisStructural EngineeringBuckling AnalysisSpacecraft StructuresStructural DesignStructural LoadsStructural Performance AnalysisStructural TestingAxial CompressionBucklingLocal BucklingOperational LoadsPanel DesignPost-buckling BehaviorPostbuckling BehaviorStiffened Panel Buckling
Due to weight and cost goals, a grid-stiffened panel concept is being used for redesign of a structural component on the Minotaur OSP space launch vehicle. By designing the structural panels to carry operational loads past the point of initial buckling (local post-buckling), the resulting grid stiffened panel concept is lighter and 30 % less costly to manufacture than other design candidates such as the existing honeycomb sandwich panel concept flown today. During June 2001 in Seattle, Boeing performed a structural certification experiment of a composite, grid stiffened, cylindrical panel loaded in axial compression. Pretest predictions were made for linear elastic (bifurcation) buckling, and non-linear post buckling. The tools used for pretest analysis were HyperSizer, and the FEM based tools MSC/NASTRAN and STAGS. Local buckling of the facesheet triangular shaped skin pocket occurred at a load of around 230 (lb/in). The test panel was able to sustain considerable additional loading, with post buckling failure occurring at 1320 (lb/in). The HyperSizer post buckling pretest prediction was 1300 (lb/in), the STAGS pretest prediction was 1250 (lb/in), and the MSC/NASTRAN pretest prediction ranged
2