Circulation · 2006 · 79 citations · 36 references
MedicineCardiologyRadiologyDiagnostic ImagingDiagnostic RadiologyInterventional CardiologyAortic ImagingBalloon AngioplastyCardiovascular ImagingMagnetic Resonance ImagingContrastContrast Agent Signal EnhancementImage Distortion ReductionInterventional Guidance
BACKGROUND: MRI guidance of percutaneous transluminal balloon angioplasty (PTA) of aortic coarctation (CoA) would be desirable for continuous visualization of anatomy and to eliminate x-ray exposure. The aim of this study was (1) to determine the suitability of MRI-controlled PTA using the iron oxide-based contrast medium Resovist (ferucarbotran) for catheter visualization and (2) to subsequently apply this technique in a pilot study with patients with CoA. METHODS AND RESULTS: The MRI contrast-to-noise ratio and artifact behavior of Resovist-treated balloon catheters was optimized in in vitro and animal experiments (pigs). In 5 patients, anatomy of the CoA was evaluated before and after intervention with high-resolution respiratory-navigated 3D MRI and multiphase cine MRI. Position monitoring of Resovist-treated catheters was realized with interactive real-time MRI. Aortic pressures were continuously recorded. Conventional catheterization was performed before and after MRI to confirm interventional success. During MRI, catheters filled with 25 micromol of iron particles per milliliter of Resovist produced good signal contrast between catheters and their background anatomy but no image distortion due to susceptibility artifacts. All MRI procedures were performed successfully in the patient study. There was excellent agreement between the diameters of CoA and pressure gradients as measured during MRI and conventional catheterization. In 4 patients, PTA resulted in substantial widening of the CoA and a decrease in pressure gradients. In 1 patient, PTA was ineffective. CONCLUSIONS: The MRI method described represents a potential alternative to conventional x-ray fluoroscopy for catheter-based treatment of patients with CoA.
36
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
David J. Brenner, Carl D. Elliston, Eric J. Hall et al. · American Journal of Roentgenology · 2001 · 3.2K citations
Medicine, Pediatrics, Radiology +17
Magnetic Resonance Imaging Analysis of Right Ventricular Pressure-Volume Loops
Titus Kühne, Sevim Yilmaz, Paul Steendijk et al. · Circulation · 2004 · 370 citations · Full text
Medicine, Cardiology, Radiology +16
Cardiac catheterisation guided by MRI in children and adults with congenital heart disease
Reza Razavi, Stephen Keevil, Marc E. Miquel et al. · The Lancet · 2003 · 335 citations
Medicine, Cardiology, Radiology +14
Patient-Specific Dose and Radiation Risk Estimation in Pediatric Cardiac Catheterization
Klaus Bacher, E. Bogaert, Régine Lapere et al. · Circulation · 2004 · 273 citations
Medicine, Cardiology, Pediatrics +17