Luminescent Labels—More than Just an Alternative to Radioisotopes?

Andreas Mayer, Stephan Neuenhofer

Angewandte Chemie International Edition in English · 1994 · 203 citations · 213 references

Concepts

TL;DR

Traditional chemical, chromatographic, and spectrometric methods lack sensitivity for nano‑ and subnanogram detection, whereas the radioimmunoassay introduced high sensitivity and specificity, but radioactivity’s drawbacks spurred the development of nonradioactive luminescent labels that now replace isotopes and reach unprecedented sensitivity. The article reviews luminescent labeling methods and their applications in immunoassays. It surveys the design and implementation of enzyme, fluorophore, and luminophore‑based luminescent assays used in immunoassays. Luminescent labels not only replace radioisotopes but also enable detection of trace substances with sensitivity beyond what was previously attainable.

Abstract

Abstract Chemical, chromatographic, or spectrometric methods are generally unsuitable for the detection of molecules in the nano and subnanogram region because of their low sensitivity. The radioimmunoassay (RIA) developed by Yalow and Berson in 1959 combined the high sensitivity of radioactively labeled substances with the high specificity of immunological reactions for the first time. In this way it was possible to detect quantitatively the tiniest traces of substances in the presence of an excess of other, in some cases, similar foreign substances without prior enrichment. Immunoassays have certainly developed to become the most valuable analytical tool of in vitro diagnostics and are today routinely employed for the detection of endogenous and exogenous substances (e.g. hormones, tumor‐associated proteins, bacteria, viruses, toxins, drugs, etc). The many disadvantages of radioactivity such as the required handling licenses, disposal costs, precautions necessary to prevent risks to health, short shelf‐life, and limited sensitivity soon led to the search for other nonradioactive labeling methods. Encouraged by the development of light measuring techniques and the commercial availability of highly sensitive apparatus, radioactive isotopes as labels are today being replaced increasingly by enzymes, fluorophores, or luminophores. Some of the new luminescent labels have, however, not only facilitated replacement of radioisotopes, but also a breakthrough into what has until now been unattainable levels of sensitivity. The following article reviews the methods of luminescent labeling and their applications mainly in the area of immunoassays.

References

213