American Journal of Roentgenology · 2004 · 84 citations · 32 references
MedicineOrthopaedic SurgeryRadiologyDiagnostic ImagingDiagnostic RadiologyOrthopedicsCartilage ImagingImaging AssessmentMagnetic Resonance ImagingMedical ImagingMusculoskeletal ImagingOrthopedic ImagingCartilage Injury ImagingDiagnostic Performance MetricsOsteoarthritis UltrasonographyRadiography Of The HipUltrasound Of The Hip
OBJECTIVE: The objective of our study was to compare the diagnostic performance of a dedicated cartilage MR sequence (water-excitation 3D double-echo steady-state) with a standard MR sequence (T1-weighted spin-echo) in detecting articular cartilage lesions of the hip after intraarticular injection of gadopentetate dimeglumine. MATERIALS AND METHODS: In 50 MR arthrograms of the hip joint obtained in 47 consecutive patients, a sagittal 3D double-echo steady-state sequence (TR/TE, 24/6.5; flip angle, 25 degrees ) was compared with a sagittal T1-weighted spin-echo sequence (350/14). Two musculoskeletal radiologists independently evaluated articular cartilage. Sensitivity and specificity for detecting cartilage defects were calculated for those hips that underwent open surgery (n = 21). Lesion conspicuity was retrospectively reviewed and graded between 1 (not visible) and 5 (well defined). RESULTS: At surgery, a total of 26 lesions of the acetabular (n = 20) and femoral (n = 6) cartilage were found. For the 3D double-echo steady-state and T1-weighted spin-echo sequences, sensitivities and specificities for cartilage lesion detection were 58% and 88% and 81% and 81% for reviewer 1 and 62% and 94% and 62% and 100% for reviewer 2, respectively. Lesion conspicuity was significantly superior (p = 0.036) for the 3D double-echo steady-state sequence (mean grade, 3.4) compared with the T1-weighted spin-echo sequence (mean grade, 3.0). The kappa value was fair for the 3D double-echo steady-state sequence (kappa = 0.40) and moderate for the T1-weighted spin-echo sequence (kappa = 0.55). CONCLUSION: The 3D double-echo steady-state sequence optimized for cartilage imaging improves lesion conspicuity but does not improve diagnostic performance.
32
The Measurement of Observer Agreement for Categorical Data
J. Richard Landis, Gary G. Koch · Biometrics · 1977 · 78.9K citations · Full text
Surgical dislocation of the adult hip
Reinhold Ganz, Emanuel Gautier, K. Ganz et al. · Journal of Bone and Joint Surgery - British Volume · 2001 · 1.3K citations
Surgical dislocation of the adult hip
Reinhold Ganz, Emmanuel L. Gautier, K. Ganz et al. · Journal of Bone and Joint Surgery - British Volume · 2001 · 1.3K citations
Femoroacetabular impingement and the cam-effect
Keita Ito, M.-A. Minka-Ii, Michael Leunig et al. · Journal of Bone and Joint Surgery - British Volume · 2001 · 761 citations · Full text